| 1. Basic Metered Rack PDU | Small server rooms, branch offices, and low-density racks | 230 V single-phase; 16 A or 32 A; up to approximately 7.4 kW at 230 V and 32 A | IEC 60320 C13/C19 outlets; commonly 8–24 outlets | Local LCD or LED display; optional Ethernet with SNMPv1/v2c | Overload protection, circuit breaker, grounded metal enclosure, IEC-compliant connectors | Total current, voltage, power, and energy at the device level | Low purchase cost and simple rack-level visibility |
| 2. Basic Switched Rack PDU | Remote sites, colocation cabinets, and equipment requiring remote reboot | 230 V single-phase; 16 A or 32 A; approximately 3.7–7.4 kW maximum before derating | 8–24 individually switched IEC C13/C19 outlets | RJ45 Ethernet, HTTPS, SSH, SNMP, and outlet-level control | Outlet sequencing, branch overload protection, user authentication, and configurable shutdown safeguards | Outlet switching plus total current, voltage, power, energy, and alarm status | Remote power cycling and controlled startup after an outage |
| 3. Advanced Metered PDU | Medium-density enterprise racks and shared data-centre environments | 230 V single-phase or 400 V three-phase; 16–32 A per feed | C13/C19 outlets; 12–36 outlets; optional outlet and bank metering | Ethernet, IPv4/IPv6, SNMPv3, Modbus TCP, and web interface | Password policies, role-based access, tamper-resistant enclosure, circuit protection, and alarm thresholds | Input, circuit, outlet-bank, and energy measurements with time-stamped alarms | Accurate capacity planning and integration with DCIM or building-management systems |
| 4. Switched and Outlet-Metered PDU | High-value racks, managed colocation, and equipment with strict power accountability | 230 V single-phase or 400 V three-phase; commonly 16–32 A per feed | Individually switched C13/C19 outlets with outlet-level current and energy readings | Dual Ethernet options, SNMPv3, HTTPS, REST API, and centralized firmware management | Per-outlet load limits, sequential restart, branch protection, audit logs, and role-based permissions | Real-time outlet-level power, current, voltage, energy, alarms, and event history | Chargeback, utilization analysis, and remote remediation of individual devices |
| 5. High-Density Three-Phase PDU | Virtualization clusters, AI-ready racks, and high-density compute zones | 400 V three-phase; typically 16–32 A; up to approximately 22 kW at 400 V, 32 A, and unity power factor | C13/C19 outlets; balanced across three phases; IEC 60309 or equivalent input plug | Dual network ports, SNMPv3, Modbus TCP, API access, and phase-level data export | Phase imbalance alarms, overcurrent protection, temperature sensing, and protective earthing | Per-phase voltage, current, power, energy, power factor, crest factor, and imbalance | Maximum usable power in limited rack space while maintaining phase balance |
| 6. Automatic Transfer PDU | Single-corded servers, network equipment, and racks requiring feed redundancy | Dual 230 V single-phase inputs; typically 16–32 A per source; output limited by the selected source | C13/C19 outlets supplied through automatic source transfer | Network monitoring, SNMP, HTTPS, dry contacts, and source-status reporting | Break-before-make transfer, source qualification, circuit breakers, and transfer-failure alarms | Both source voltages, source availability, output load, transfer events, and alarms | Maintaining power to single-corded loads when one upstream feed fails |
| 7. Environmental and Intelligent PDU | Global colocation, unmanned facilities, and racks with strict environmental targets | 230 V single-phase or 400 V three-phase; commonly 16–32 A per feed | Metered or switched C13/C19 outlets; optional locking connectors and outlet identification | SNMPv3, HTTPS, REST API, IPv6, redundant network ports, and sensor-bus support | Load alarms, temperature and humidity alerts, door or leak sensor inputs, access control, and audit logs | Power plus temperature, humidity, airflow, contact state, energy trends, and predictive alerts | Remote operations, energy optimization, and early detection of thermal or physical risks |