| Rated motor power | 5.5 kW, approximately 7.5 hp | Suitable for pumps, fans, conveyors, mixers, compressors, and general-purpose machinery within the drive’s current rating. |
| Input voltage options | Common versions include 200–240 V AC single-phase or three-phase, and 380–480 V AC three-phase | The correct voltage class must match the local electrical supply and motor nameplate. |
| Output configuration | Variable-frequency three-phase AC output; typical maximum output frequency up to 400 Hz, depending on model | Supports adjustable motor speed while maintaining controlled acceleration and deceleration. |
| Typical rated output current | Approximately 11–13 A at 380–480 V; approximately 22–25 A at 200–240 V, subject to the manufacturer’s duty rating | Output current is more important than kW alone when selecting a drive for a specific motor. |
| Control methods | V/f control is standard; sensorless vector control is common on many current models | Sensorless vector control generally provides better low-speed torque and speed regulation than basic V/f control. |
| Overload capacity | Typically 120% of rated current for 60 seconds in normal-duty applications; heavy-duty ratings vary | Heavy-load applications may require a higher-rated VFD even when the motor power is 5.5 kW. |
| Speed regulation | Typically about ±0.5% with open-loop vector control; actual performance depends on setup and motor parameters | Useful for conveyors, material handling, and process equipment requiring stable operating speed. |
| Efficiency and power factor | Drive efficiency commonly exceeds 95% at rated load; input power factor depends on design and operating point | Actual system energy savings depend on motor efficiency, load profile, and operating speed. |
| Acceleration and deceleration | Programmable ramp times, commonly from seconds to several minutes | Reduces mechanical shock and helps limit starting current in pumps, fans, and conveyors. |
| Built-in protection | Overcurrent, overvoltage, undervoltage, overload, overheating, short-circuit, and motor-stall protection are commonly included | Protection functions improve equipment safety, but they do not replace correctly sized upstream breakers and motor protection. |
| Enclosure rating | IP20 is common for control cabinets; higher IP ratings are available in selected product lines | IP20 drives generally require installation inside a suitable electrical enclosure. |
| Communication and I/O | Common interfaces include RS-485 with Modbus RTU, digital inputs, relay outputs, and analog 0–10 V or 4–20 mA inputs | Verify terminal layout, protocol implementation, and supported communication options before integration. |
| Braking functions | DC injection braking is common; dynamic braking resistor compatibility depends on the specific model | External braking hardware may be needed for rapid stopping or high-inertia loads. |
| Operating environment | Typically around -10°C to 40°C without derating; altitude and temperature limits vary by model | Confirm derating requirements for high-temperature, high-altitude, dusty, or humid installations. |
| Applicable standards | Product documentation may reference IEC 61800-5-1, IEC 61800-3, CE, or comparable market requirements | Importers should request current compliance documents for the destination country and application. |
| Common applications | Water pumps, HVAC fans, conveyors, packaging equipment, textile machinery, mixers, and light industrial machinery | Application suitability depends on starting torque, duty cycle, braking demand, ambient conditions, and motor compatibility. |